Pentair CodeLine

Search
Home About Products Technology Support Downloads Contact

4" Housings

4" End Entry 40E Series4" Side Entry 40S Series

8" Housings

8" End Entry - 80E Series8" Side Entry - 80H Series 8" Side Entry - 80S Series 8" Side Entry - 80U Series

16" Housings

16" End Entry - 160E Series 16" Side Entry - 160S Series

8" End Entry: 80E Series Membrane Housings

Models: 80E30, 80E45, 80E60, 80E100, 80E120

  • End Entry Design
  • Available in pressure rating of 300psi, 450psi, 600psi, 1000psi & 1200 psi
  • Can accommodate any standard make of 8” Membrane Element

Key Features

  • Mirror finish I.D for easy & quick loading & unloading of membranes.
  • Quick lock head retention system for quick access to membranes.
  • Exteriors coated with high gloss polyurethane paint for UV resistance.
  • ASME compliant & CE marking.

Specifications

Model Drawing # # of Elements Operating Pressure Max. Operating Temperature Qualification Pressure
80E30 99111 1-7 300 psi / 20 bar 120˚F / 49˚C 1800 psi / 124 bar
80E45 99112 1-7 450 psi / 31 bar 120˚F / 49˚C 2700 psi / 186 bar
80E60 99109 1-7 600 psi / 41 bar 120˚F / 49˚C 3600 psi / 248 bar
80E100 99108 1-7 1000 psi / 68 bar 120˚F / 49˚C 6000 psi / 413 bar
80E120 99110 1-7 1200 psi / 82 bar 120˚F / 49˚C 7200 psi / 496 bar

More Information

Product Literature

Technical Drawings: 80E30, 80E45, 80E60, 80E100, 80E120

User Guide

Spares List

Adapters List

Above specifications are subject to change. Please contact us for updated information.